Skip to content
Commit a36ed287 authored by Frank Benkert's avatar Frank Benkert Committed by Gregory Nutt
Browse files

SAMV7: MCAN: Prevent Interrupt-Flooding of ACKE when not connected to CAN-BUS....

SAMV7: MCAN: Prevent Interrupt-Flooding of ACKE when not connected to CAN-BUS. An Acknowledge-Error will occur every time no other CAN Node acknowledges the message sent. This will also occur if the device is not connected to the can-bus. The CAN-Standard declares, that the Chip has to retry a given message as long as it is not sent successfully (or it is not cancelled by the application). Every time the chip tries to resend the message an Acknowledge-Error-Interrupt is generated. At high baud rates this can lead in extremely high CPU load just for handling the interrupts (and possibly the error handling in the application). To prevent this Interrupt-Flooding we disable the ACKE once it is seen as long we didn't transfer at least one message successfully.